
XTL/XTLC Installation Guide Digital Monitoring Products
9
COMPLIANCE
False Alarm Reduction Programmable Options ANSI/SIA CP-01-2010
19.1 Shipping Defaults and Recommended Programming
SIA CP-01 FEATURE
PARAGRAPH # AND
DESCRIPTION
DMP PROGRAMMING
GUIDE LT-1108
SECTION #
REQUIREMENT RANGE
SHIPPING
DEFAULT
RECOMMENDED
PROGRAMMING*
4.2.2.1ExitTime 8.6ExitDelay
Required
(Programmable)
45sec.-250sec.
60
Seconds
60 Seconds
4.2.2.2Progress
Annunciation
13.13PrewarnAddress Allowed
Individualkeypadsmay
bedisabledperzone
All
keypads
enabled
Allkeypadsenabled
4.2.2.3ExitTimeRestart 8.6ExitDelay RequiredOption
For re-entry during exit
time
Enabled Enabled
4.2.2.5AutoStayArmon
UnvacatedPremises
8.15OccupiedPremise
-SeeInstallGuide
RequiredOption
(exceptfor
remotearming)
OccupiedPremiseNO/
YESoption
Enabled
EnabledYes
for Residential
Applications
4.2.4.4ExitTimeand
Progress Annunciation/
Disable-forRemoteArm
NotAvailableon
Remote Arming
AllowedOption
Progress Annunciation
Always disabled for
Remote Arming
Not
Available
Remote Arming not
allowed for CP-01
installations.
4.2.3.1EntryDelay(s) 8.5EntryDelay
Required
(Programmable)
OnlyuseEntry
Delay1.Donot
useEntryDelay2.
30sec.–240Sec.**
30
Seconds
Atleast30
Seconds **
4.2.5.1AbortWindow–
forNon-FireZones
3.3TransmitDelay RequiredOption
Disablebyzoneorzone
type
Enabled
NTDYEX
Zone
Enabled
4.2.5.1AbortWindow
Time–forNon-FireZones
3.3TransmitDelay
Required
(Programmable)
20sec.,30sec.,or
40sec.**
30
Seconds
Atleast20
Seconds **
4.2.5.1.2Abort
Annunciation
3.3TransmitDelay RequiredOption
Annunciate that no
alarm was transmitted
Yes Yes
4.2.5.4.1Cancel
Annunciation
AlwaysEnabled-Not
Programmable
RequiredOption
Annunciate that a
Cancel was transmitted
(S49)
Always
Enabled
Yes
4.2.6.1&4.2.6.2Duress
Feature
UserCode+1=
AmbushCodeNot
Available
AllowedOption
No1+derivativeof
another user code/no
duplicates with other
user codes
Code+1
Always
Disabled
NotProgrammable
4.3.1CrossZoning 13.16CrossZone RequiredOption
Yes/NoZone
Programming
No
Enabledusing
two or more
programmedzones
4.3.1ProgrammableCross
Zoning Time
8.7CrossZoneTime Allowed 4sec.-250sec. 0 Seconds
Perwalkpathin
protected premises
4.3.2SwingerShutdown
NotAvailable—Always
On
Required 1-6 trips 2trips 2trips
4.3.2SwingerShutdown
Disable
13.12SwingerBypass Allowed
For non-police response
zones
Yes Enabled(allzones)
4.3.3FireAlarm
Verication
13.5ZoneType RequiredOption FV Type Zone No
Yes as required
(unlesssensorscan
selfverify)
4.6.3SystemTest 16.6WalkTest Allowed
Test all protection
devices
N/A N/A
4.6.5Communications 16.6WalkTest NotAllowed N/A N/A N/A
* Programming at installation may be subordinate to other listed requirements for the intended application.
**ForlistedInstallations,combinedEntryDelayandTransmitDelayshouldnotexceed1minute.
LocalBell
Allnon-rezonessuchasNight,Day,Exit,Aux1andAux2mustbeprogrammedforlocalbellenabledwithabellcutofftimeset
toaminimumof6minutestoprovideacancelwindowof5minutesorgreater.Thisdoesnotapplytomanuallyoperatedzone
typessuchasPanicandEmergency.
TherequirementsaresupersededbyanyrequirementsforCommercialBurglar,HouseholdFireWarning,orHouseholdBurglar
applications.
MinimumInstallationRequirements:SIACP-01-2010minimumsysteminstallationrequirementsincludeanXTL/XTLC,an1135
WirelessSiren,a9000SeriesWirelesskeypad,andcommunicationtoanSCS-1Rreceiver.
Komentáře k této Příručce