Introduction
XRSuper6/XR20/XR40 Installation Guide
3
2500 N. Partnership Boulevard Springfield, MO 65803 www.dmpnet.com Digital Monitoring Products
System Components
3.1 Description
The DMP system is made up of an alarm panel with built in communicator, an enclosure, a 16.5 VAC transformer,
and a 12 VDC 7.0 Ah battery. You can add Security Command keypads to the system and can also connect auxiliary
devices to the panel's open collector outputs to expand the basic system. Combined current requirements of
additional modules may require an auxiliary power supply. Refer to the Standby Battery Power Calculation section
in this guide when calculating power requirements. In addition, up to 32 points of zone expansion can be added to
the XR40, 16 points to the XR20, and 16 points to the XRSuper6.
3.2 Wiring diagram
The system wiring diagram in Figure 1 shows some of the accessory devices you can connect for use in various
applications. A complete description of each module follows. Zone expanders can be added to the XRSuper6,
XR20, and XR40. Wireless interface can also be added to the XRSuper6, XR20, and XR40.
3.3 Lightning protection
Metal Oxide Varistors and Transient Voltage Suppressors help protect against voltage surges on input and output
circuits. A transorb is provided for the Smoke Detector Output Circuit (Terminal 11). This transient protection
provides additional resistance to electrical surges such as lighting. Additional surge protection is available by
installing the DMP 370 or 370RJ Lightning Suppressors.
3.4 Command Processor Accessories
You can connect any combination (up to four on XRSuper6 and XR20, and up to eight on XR40) of Model 670,
770, and 771 vacuum fluorescent, 790, 791, and 793 LCD, or 692 LED Security Command Keypads to the 4-wire
keypad data bus provided by the panel on terminals 7, 8, 9, and 10. Also, you can connect Model 714, 715, 714-
8, 714-16, 715-8, 715-16 zone expanders to the XR40, XR20, or XRSuper6 keypad bus. Additionally, you can
connect one Model 738A Ademco Interface Module or one Model FA426 Wireless Receiver to the XRSuper6, XR20,
and XR40 keypad bus. You can connect an additional Model FA426 Wireless Receivers to the XR40 keypad bus.