18
SySTem oPTionS
6.15
HOUSE CODE: 0
House Code
When using a DMP wireless system, enter a house code between 1 and 50 for the
wireless system to use. The DMP wireless receiver automatically programs the house
code into the wireless transmitters when the unique transmitter serial number is
programmed into the panel. See Wireless programming in Zone Information. Default
is 0 (zero) indicating the DMP wireless system is not being used.
The house code identies the panel, receiver, and transmitters to each other. When
operating, the receiver listens for transmissions that have the programmed house
code and transmitter serial number.
Note: The exibility of DMP two-way wireless operation allows an existing house code
to be changed in the panel at any time. The transmitter may take up to two minutes
to learn the new house code and continue operation.
Note: When any wireless zone programming is changed in the panel, wireless
receiver zone programming is updated by the panel. At that point, all wireless zones
display as normal for up to 1 minute, regardless of the actual state of the zone.
6.16
DET JAMNG NO YES
Detect Wireless Jamming
This option displays when the House Code entered is for a DMP 1100D Series Wireless
system. When enabled and the receiver detects jamming, a trouble or alarm
message is sent to the receiver and displays in the Status List. Select YES to enable
jamming messages to display in the Status List. Select NO to disable jamming
messages. Default is NO.
6.17 Wireless Audible Annunciation
This option displays when the House Code entered is for a DMP 1100 Series Wireless
system (1-50). Press any top row key to select the keypad buzzer annunciation
method for wireless low battery and missing messages. Select ANY to enable
annunciation anytime. Select DAY to enable annunciation except during sleeping
hours (9 PM to 9 AM). Select MIN (minimum) to annunciate only Fire and Fire Verify
zones during daytime hours (9 AM to 9 PM). Default is DAY.
6.18
KPD PANCS NO YES
Enable Keypad Panic Keys
This option allows the two-button panic key operation selected at a keypad to send
the Panic, Emergency, or Fire message to the central station receiver. Select YES to
enable the two-button panic operation. To disable the two-button panic operation,
select NO. Default is YES.
6.19
SIA CP-01 NO YES
SIA CP-01
Select YES to allow the panel to operate according to ANSI/SIA CP-01 standards for
the following operations. Select NO to enable standard DMP operation. Default is
YES. When YES is selected:
Power Up and Stop Routine
the 60 second zone startup delay is turned on.
Keypress Alarm Silence
during an alarm, the keypad alarm and bell output turn off when the rst key is
pressed at a keypad.
Entry Delay
entering the rst digit of a code at the keypad stops the prewarn tone.
Exit Delay
the keypad displays the Exit Delay time countdown and annunciates a tone at
8 second intervals until the last 10 seconds when annunciation is at 3 second
intervals.
Exit Error Operation
When the exit zone is faulted (door still open) at the end of the exit delay:
the bell sounds for the length of time set in Bell Cutoff programming
the Entry Delay operation starts, requiring code entry to disarm
if not disarmed, a zone alarm and an Exit Error are sent to the receiver.
Automatic Disarming Operation
For All/Perimeter or Home/Sleep/Away systems the Interior automatically
disarms if a Perimeter exit zone is not tripped during the Exit Delay time when
arming All or Away at the keypad.
ANY DAY MIN
WLS AUDIBLE: DAY