XR500 Series Programming Guide Digital Monitoring Products
43
AreA InformAtIon
Area Information
18.1
AREA INFORMATION
Area Information
Allows you to assign functions to the different areas in the system. All non-24-hour zones
must be assigned to an active area. See Zone Information.
You activate an area by assigning it a name. See Area Name. A name is given to each
active area in place of a number to assist the user during arming and disarming.
When only areas one to eight are used, the Armed Status display is 1 2 3 4 5 6 7 8. When
areas nine or higher are used the system Armed Status display reads ALL SYSTEM ON or
SYSTEM ON. Press the COMMAND key to display additional areas. Refer to the Multiple
Displays section at the beginning of this document and in the XR500 User’s Guide (LT-
0683).
18.2
EXIT DELAY: 60
Exit Delay
Enter the exit delay time for all Exit type zones in this area. When the exit delay time
starts, all activity on that zone and other non-24-hour zone types in the area is ig nored
until the exit delay expires. The keypad displays the Exit Delay time countdown and
annunciates the Exit Delay tone at 8 second intervals until the last 10 seconds when
annunciation is at 3 second intervals.
The exit de lay can be from 30 to 250 sec onds. Default is 60 seconds.
During Exit Delay, if an exit zone trips, then restores, and trips again, the Exit Delay
timer restarts. This restart can occur only once.
Exit Error Operation: At arming, when an entry/exit zone (EX) is faulted at the end of
the exit delay then one of two sequences occur:
For Entry Delay 1 EX type zones:
• the bell sounds for the length of time set in Bell Cutoff programming.
• the Entry Delay operation starts requiring code entry to disarm
• if not disarmed, a zone alarm and an exit error are sent to the receiver.
For Entry Delay 2-4 EX type zones:
• the zone is force armed and a zone force arm message is sent to the receiver
• an Exit Error is sent to the receiver
• the bell sounds for the length of time set in Bell Cutoff programming
18.3
BURG BELL OUT: 0
Burglary Bell Output
Enter the output number (0 to 6, 500 to 999, G1 to G20, or D1 to D16) that is turned
on any time a Burglary type zone is placed in alarm. The output is turned off when you
disarm any area and no other Burglary type zones are in alarm. The output can also be
turned off using the Alarm Silence option in the User Menu or by entering a user code
with the authority to silence alarms. The duration of this bell output follows the time
entered in the System Options>Bell Cutoff Time option. See the Output Options - Bell
Cutoff Time section. If Bell Test is selected YES, the Burglary Bell Output entered here is
turned on for two seconds each time the system is armed.
18.4
O/C RPTS NO YES
Opening/Closing Reports
This option allows an Opening report to be sent to the receiver whenever any area is
disarmed. A Closing report is also sent to the receiver when any area is armed.