23.11 Keypad Bus and LX-Bus Zone Type Descriptions
This section describes applications for the default Keypad and LX-Bus zone types in Zone Information
programming.
-- (Blank Zone)
Customizable zone type. By default, no actions are programmed to occur with Blank Zone. A zone name must be
entered to use this zone type: This zone type is not the same as an *UNUSED* zone.
NT (Night Zone)
Controlled instant zone used for perimeter doors and windows and interior devices such as PIRs and Glassbreak
detectors.
DY (Day zone)
Used for emergency doors or re doors to sound the keypad buzzer and display the zone name when the zone is
faulted. Day zones also send alarm reports to the receiver during the system armed periods.
EX (Exit zone)
Initiates the entry delay timer when its assigned area is fully armed. Also, can initiate an exit delay timer to
allow a user to exit an area after the arming process starts.
PN (Panic zone)
Used for connecting to mechanical devices that allow a user to signal an emergency alarm. Panic zones can
provide either a silent or audible alarm with or without reporting to a central station receiver.
EM (Emergency zone)
These are used for reporting medical or other non-panic emergencies to the central station receiver.
SV (Supervisory zone)
Used to provide 24-hour zone supervision to devices associated with re systems. Typical applications are
tamper switches on Post Indicator Valves (PIVs), gate valves, and low and high temperature gauges.
FI (Fire zone)
Used for any type of powered or mechanical re detection device. Typical applications are for smoke detectors,
sprinkler owswitches, manual pull stations, and beam detectors. Retard, cross zoning, and presignal options
are available for the Fire zone type.
FV (Fire Verify zone)
Used primarily for smoke detector circuits to verify the existence of an actual re condition. When a Fire Verify
zone initiates an alarm, the panel performs a Fire Reset. If any Fire Verify zone initiates an alarm within 120
seconds after the reset, an alarm is indicated. If an alarm is initiated after 120 seconds, the cycle repeats.
A1 and A2 (Auxiliary 1 and Auxiliary 2)
These zones are similar to a Night zone and are typically used to protect restricted areas within a protected
premises.
AR (Arming zone)
This zone allows you to connect a keyswitch to a zone and use it to arm and disarm one or more areas.
23.12 ZoneTypeSpecications
The XR500 Series panel contains multiple default zone types for use in conguring the system. These zone
types provide the most commonly selected functions for their applications. All zone types can be customized by
changing the variable options listed below. The Keypad Bus Zone Information table below reects the zone types
for Keypad Bus Zones. The XR500 Series LX-Bus Zone Information table on the next page reects the zone types
for LX-Bus Zones.
Keypad Bus Zone
Information
Type Area Fire
Bell
Disarmed
Open
Disarmed
Short
Armed
Open
Armed
Short
Swinger
Prewarn
Entry Delay
Retard Delay
Presignal
Fast Response
Cross Zone
Priority
Follow Area
Real-Time Rprts
Door Number
Style
Assign Disarm condition of
NT, DY, EX, A1, and A2 only
Assign Prewarn and Entry
Delay for EX only
Assign Retard and Presignal
for FI, SV, A1, and A2 only
Zone Type Defaults
--
DY
FI
NT
EX
PN
SV
A2
AR
INT
PERIM
BDRM
or
1
to
32
Output *
Message
Output *
Action
Message
Output *
Action
Message
Output *
Action
Message
Output *
Action
A
T
L
-
D
S
C
S
P
M
F
A
T
L
-
D
S
C
S
P
M
F
A
T
L
-
D
S
C
S
P
M
F
A
T
L
-
D
S
C
S
P
M
F
N
or
Y
1
to
16
1
or
4
N
or
Y
1
to
16
N
or
Y
N
or
Y
N
or
Y
0
to
16
N
or
Y
0
to
16
TGL
ARM
DIS
STEP
MNT
Night NT - 0 S - 0 S A 0 S A 0 S Y N N N 0 N 0
Day DY T 0 S T 0 S A 0 S A 0 S Y N N N 0 N 0
Exit EX - 0 S - 0 S A 0 S A 0 S Y
1-16
1 N N N N 0
Fire FI 0 T 0 S A 0 S N N + N N N
Panic PN T 0 S A 0 S N N N N
Emergency EM T 0 S A 0 S N N N N
Supervisory SV 0 T 0 S A 0 S N N + N N N
Auxiliary 1 A1 T 0 S A 0 S T 0 S A 0 S N N + N N N 0 N 0
Auxiliary 2 A2 T 0 S A 0 S T 0 S A 0 S N N + N N N 0 N 0
Fire Verify FV 0 T 0 S A 0 S N N N
Arming AR TGL
*Output Options: 1 to 6, 450 to 474, 480 to 499, 500 to 999, D1 to D16, G1 to G20. + = Set retard to YES before selecting presignal. = Zone functions not available.