Digital Monitoring Products XR100 Series Installation Guide
6
INTRODUCTION
XR100 Series Installation Guide Digital Monitoring Products
7
INSTALLATION
Installation
4.1 Mounting the Enclosure
The metal enclosure for the XR100 Series must be mounted in a secure, dry place to protect the panel from damage
due to tampering or the elements. It is not necessary to remove the XR100 Series PCB when installing the enclosure.
Figure 2 shows the mounting hole locations for both the Model 350/350A Enclosures.
Note: When using the XR100 Series panel for UL Listed applications, use the Model 350, 349, 341, 342, or 352S
enclosure for standby batteries. When using the 352S in UL listed applications, the enclosure must be surface
mounted on the wall.
Figure 2: XR100 Series in Model 350 or 350A Enclosure
4.2 Mounting Keypads and Zone Expansion Modules
DMP LCD keypads have removable covers that allow you to easily mount the keypad to a wall or other at surface
using the screw holes on each corner of the base. Before mounting the base, connect the keypad wire harness leads
to the keypad cable from the panel and to any device wiring run to that location. Then attach the harness to the
pin connector on the PC board, mount the base, and install the keypad cover making sure all of the keys extend
through their respective holes.
For mounting keypads on solid walls, or for applications where conduit is required, use the Model 695 1-1/2” deep or
the Model 696 1/2” deep backboxes.
The DMP 711, 712-8, 714, 715, 716, and 717 modules are each contained in molded plastic housings with removable
covers. The base provides you with mounting holes for installing the unit to a wall, switch plate, or other surface.