Digital Monitoring Products XR100 Series Installation Guide
20
COMPLIANCE
XR100 Series Installation Guide Digital Monitoring Products
21
COMPLIANCE
Universal UL Burglary Specications
19.1 Introduction
The programming and installation specications contained in this section must be completed when installing the
XR100 Series panel in accordance with any of the UL burglary standards. Additional specications may be required by
a particular standard.
19.2 Wiring
All wiring must be in accordance with NEC, ANSI/NFPA 70, UL 681, and UL 827 for all burglary installations. All
transformer wires must be installed in conduit.
19.3 Control Outside of Protected Area
A Potter EVD or Sentrol 5402 should be used in place of a lined cabinet when the panel is installed outside of the
protected area. Front and rear tamper switches are required. Refer to the system wiring diagram and Figure 2.
19.4 Police Station Phone Numbers
The digital dialer telephone number programmed for communication must not be a police station phone number.
19.5 Bypass Reports
The Bypass Reports option must be programmed as YES for all UL burglary applications. See the XR100 Series
Programming Guide (LT-0896).
19.6 System Maintenance
To ensure continuous satisfactory operation of any alarm system, proper installation and regular maintenance by the
installing alarm company and frequent testing by the end user is essential. Offering a maintenance program and
acquainting the user with the correct procedures for system use and testing is also the responsibility of the installing
alarm company.
19.7 UL Listed Receivers
UL has veried operation with the DMP SCS-1 and SCS-1R, Sur-Gard SG-HLR2-DG, FBII CP220PB, Osborne-Hoffman
Quick-Alert, and Radionics D6500 receivers. It is the installer’s responsibility to verify compatibility between the
XR100 Series and the receiver used during installation. The installer shall verify the compatibility of the receiver
and the system on a yearly basis.
19.8 Power Supply Supervision
For commercial burglary applications the power supply for all local bells shall be under 24-hour protection. Refer to
section 6 in this document.
19.9 Wireless Tamper
The Zone Information Disarmed Open Message to Transmit must be programmed Trouble (T). See the XR100 Series
Programming Guide (LT-0896). (Not applicable to UL 1023.)
19.10 Wireless External Contact
When used, the External Contact of 1101 or 1102 must be programmed Normally Closed. XR100 Series Programming
Guide (LT-0896).
19.11 Wireless Supervision Time
The Zone Information Supervision Time cannot be set to 0 (zero). XR100 Series Programming Guide (LT-0896).
19.12 Detect Wireles Jamming
The Detect Wireless Jamming option must be programmed YES. See the XR100 Series Programming Guide (LT-0896).
(Not applicable to UL 1023.)