12
XRSuper6/XR20/XR40 Programming Guide
Digital Monitoring Products www.dmpnet.com 2500 N. Partnership Boulevard Springfield, MO 65803
5.1 SYSTEM REPORTS
This function allows you to select the reports the XRSuper6/XR20/XR40 send to the
receiver.
5.2 OPENING/CLOSING REPORTS
This option allows the selection of Opening/Closing Reports and the number of
reports sent to the receiver.
NO - Opening/Closing Reports are not sent by the panel.
YES - The panel will send Opening/Closing Reports for each programmed area.
LTD - The panel sends only one opening and one closing report. When LTD is
selected and all areas become armed, the panel sends a General Closing Report.
Then after the first disarming, the panel sends a General Opening Report.
Therefore, when LTD is selected the panel will only send a report after all areas are
armed and then at the first disarm of an area. All openings and closings will be
logged in the event buffer. This option is only available when the communication
type is CID or M2E. Refer to the Communication Type section.
ALM - The panel sends only one opening report if an alarm has occurred during the
last armed cycle. The panel will send a General Opening Report. The panel does not
send closing reports when ALM is selected. All other openings and closings will be
logged in the event buffer. This option is only available when the communication
type is CID or M2E. Refer to the Communication Type section.
5.3 ABORT REPORT
YES allows the panel to send an alarm abort report to the receiver any time an area
is disarmed after an alarm report has been sent and the Bell Cutoff Time has not
expired. See the Bell Cutoff section. The area must be disarmed and no alarmed
zones can still be armed. YES also allows a Bell Silenced Report to be sent if the
alarm bell is silenced with a valid user code during an alarm, if the communication
type is set to DD. When the system is disarmed during an alarm, only Abort and
Opening Reports are sent. Abort reports are also sent when the system is disarmed
during Transmit Delay and the Bell Cutoff Timer is active.
Note: Abort reports will not be sent for Fire zones, Fire Verify, or Supervisory type
zones.
5.4 ZONE RESTORAL REPORTS
This option allows you to specify whether the panel sends zone restoral reports and
also when they will be sent.
NO - Restoral reports are not sent by the panel.
YES - The panel always sends zone restoral reports at the time the zone restores
from an alarm or trouble condition.
DISARM - The panel sends zone restoral reports when a zone that has restored from
an alarm or trouble is disarmed. Twenty-four hour zones send restorals immediately.
5.5 BYPASS REPORTS
YES allows the panel to send all zone bypass, reset, and force arm reports to the
receiver. The bypass report includes the zone number, zone name, and the user
number of the individual bypassing the zone.
5.6 CODE CHANGE REPORTS
YES allows the panel to send all code additions, changes, and deletions to the
receiver. The code change report includes the user number added or deleted and
the user number of the individual making the change.
5.7 AMBUSH
YES allows an ambush report to be sent any time user code number one is entered at
a keypad. Selecting NO disables the ambush report and allows user code number one
to operate the same as all other codes.
RESTORAL: YES
NO YES DISARM
BYPASS YES
CODE CHG NO
AMBUSH NO
SYSTEM REPORTS
SYSTEM REPORTS
ABORT NO
OPN/CLOS NO
NO YES LTD ALM