8.1 AREA INFORMATION (XR20/XR40 Only)
This section allows you to assign functions to individual areas for XR20 and XR40
panels. All non-24 hour zones must be assigned to an active area. See the section
on Zone Information.
Note: The Area Information programming is only available on the XR20 and XR40
panels.
You activate an area by assigning it a name. A name is given to each active area in
place of a number to assist the user during arming and disarming.
8.2 AREA NUMBER
Enter the number of the area you are programming. In an area system, select from
areas 1 to 4. In an All/Perimeter system, select INTerior or PERIMeter. In a Home/
Away system, select INTerior, PERIMeter, or BEDROOMS.
8.3 AREA NAME
In an area system, you can enter up to 16 characters for the area name. Only those
areas given names can have zones assigned to them. All others are marked
*UNUSED*. Refer to the Entering Alpha Characters section.
To add an area name to the system, press any Select key and then enter up to 16
characters for the new name. Press COMMAND to continue.
To mark an active area as unused, delete the old name by pressing a Select key then
press the COMMAND key. The panel automatically sets the name as *UNUSED*. If
you have already Initialized the panel, all areas will be marked as *UNUSED*. See
section 2.3.
8.4 AUTOMATIC ARMING
Select YES to allow this area to arm automatically according to the schedule.
If Closing Check is selected as YES, the automatic arming does not take place until
the expiration of a 10-minute Closing Check delay. If the area has been disarmed
outside a schedule, the Closing Check delay occurs one hour after the area is
disarmed.
At arming, bad zones are handled according to the option selected in Bad Zones. If a
Closing report is sent, the user number is indicated as SCH on the SCS-1 Receiver.
Select NO to disable automatic arming for this area.
8.5 BAD ZONES
At the time of automatic arming, some zones in the area may not be in a normal
condition. This option allows you to program the panel's response to these bad
zones. This option is not displayed if AUTO ARM is NO.
BYP - All bad zones are bypassed. A report of the bypass is sent to the receiver if
Bypass Reports has been selected as YES. See the Bypass Reports section. The
report indicates SCH as the user number.
FORC - All bad zones are force armed. Zones force armed in a bad condition are
capable of restoring into the system and reporting alarms if tripped. A report of the
force arm is sent if Bypass Reports is YES. See the Bypass Reports section. The
report indicates the user number as SCH.
REF - The automatic arming is refused and no arming takes place. A No Closing
report is sent to the receiver regardless of the Closing Check selection. See the XR20
and XR40 Programming Sheets.
8.6 AUTOMATIC DISARMING
Select YES to allow this area to automatically disarm according to a schedule. If an
Opening report is sent, the user number is indicated as SCH. Select NO to disable
automatic disarming by schedule for this area.
AREA INFORMATION
AREA INFORMATION
AREA NO: –
* UNUSED *
AUTO ARM NO
BAD ZONES: BYP
BYP FORC REF
AUTO DIS NO