XR150/XR350/XR550 Series Installation Guide Digital Monitoring Products
19
InstallatIon
If the XR150/XR350/XR550 Series causes harm to the telephone network, the telephone company will notify you
in advance that temporary discontinuance of service may be required. But if advance notice isn’t practical, the
telephone company will notify the customer as soon as possible. Also, you will be advised of your right to le a
complaint with the FCC if you believe it is necessary.
The telephone company may make changes in its facilities, equipment, operations or procedures that could affect
the operation of the equipment. If this happens the telephone company will provide advance notice in order for you
to make necessary modications to maintain uninterrupted service.
If trouble is experienced with the Model XR150/XR350/XR550 Series, for repair or warranty information, please
contact DMP at the address and telephone number listed on the back of this document. If the equipment is causing
harm to the telephone network, the telephone company may request that you disconnect the equipment until the
problem is resolved. If your premises have specially wired alarm equipment connected to the telephone line, ensure
the installation of the panel does not disable your alarm equipment. If you have questions about what will disable
alarm equipment, consult your telephone company or a qualied installer.
Caution: To ensure proper operation, this equipment must be installed according to the installation instructions in
this manual. To verify that the equipment is operating properly and can successfully report an alarm, this equipment
must be tested immediately after installation, and periodically thereafter, according to the test instructions in this
document and the XR150/XR350/XR550 Series Programming Guide (LT-1232). Additionally, verication of Line Seize
capability should be made immediately after installation, and periodically thereafter, in order to ensure that this
equipment can initiate a call even when other equipment (telephone, answering system, computer modem, etc.)
connected to the same line is in use.
Reset and Tamper Headers
18.1 J16 Reset Header
The reset header is located to the left of the J7 Expansion Header on the right
side of the circuit board and is used to reset the XR150/XR350/XR550 Series
microprocessor. To reset the panel when rst installing the system, install the
reset jumper before applying power to the panel. After connecting the AC and
battery, remove the reset jumper.
To reset the panel while the system is operational, for example, prior to
reprogramming, install the reset jumper without powering down the system.
Remove the reset jumper after one or two seconds.
After resetting the panel, begin programming within 30 minutes If you wait
longer than 30 minutes, you must reset the panel again.
18.2 J4 Tamper Header
The J4 header is for use with the optional DMP 306 Tamper Harness. The
harness connects to one or more tamper switches mounted inside the panel
enclosure to supervise against unauthorized enclosure opening or removal.
Refer to the wiring diagram on the enclosure door for correct tamper switch
wiring.
How the Tamper Works
If the enclosure is opened or removed while one or more of the system areas
are armed, a panel tamper alarm is indicated. If all areas are disarmed, a
panel tamper trouble is indicated.
Figure 12: XR550 Series Panel
Showing the Reset Jumper
Momentarily place the Reset
jumper over both of the J16
pins to reset the panel.
K