System Link User’s Guide 15
Zone#
: This field determines how many digits may be assigned to report a zone number.
This number should correlate with the number of digits of the zones that report to the
panel. For example, the XR200 panel has zones 1-299. So you would want to set this to 3
to allow all 299 zones to report. If you are using an SCS-1 or SCS-1R Receiver this number
must match the zone number programmed in the Host/Net setup programming on the
receiver.
User#
: Select the number of digits used to report a user number. Select 3 to allow 999
users. If you are using an SCS-1 or SCS-1R Receiver, this number must match the User
number programmed in the Host/Net setup programming on the receiver.
Default Receiver:
(Must have a module to Use) Refer to the module User’s Guide for
more information.
Modem Tab
Use the Modem tab to configure System Link when
connecting to a DMP 462FM 9600 Baud Modem
installed on a panel or when connecting to an
XR500 Series or XR100 Series for programming at
2400 baud through the panel dialer. This allows
you to connect to the panel using a standard
computer modem.
Communication Options
COM Port
: Select the COM port that is connected
to your modem.
Baud Rate
: Set the baud rate for System Link to communicate with the computer modem.
Default setting is 9600.
Flow Control
: Select the flow control option recommended by your modem manufacturer.
The default setting is Hardware. If the modem does not operate correctly with the default
Hardware setting, select XON/XOFF, also known as software flow control. If neither setting
operates correctly, select None. For more information see your modem documentation.
Tone Dial
: Leave this box checked unless the phone line connected to the modem on your
System Link computer is connected to a phone line that cannot process touch-tone dialing.
General Options
Dial Timeout:
Enter the length of time System Link will wait for the XR500 Series, XR100
Series, or 462FM to pick up.
Modem Initialization String:
If an initialization string is required for the modem
communicating to the panel, enter the setup string here. The string can be up to 32
characters long.
Special Initialization String:
The special initialization string required to ensure the
modem communicates consistently at a slower baud rate is entered here. The string can
be up to 32 characters long.
Note: Only one initialization string can be used. Select the correct one for your operation.
See Panel Information on page 28.