Digital Monitoring Products XR100 Series Canadian Installation Guide
14
InstallatIon
Protection Zones
10.1 Terminals 13–24
Zones1to8(terminals13to24)ontheXR100Seriespanelareallgroundedburglaryzones.Forprogrammingpurposes,
thezonenumbersare1through8.Listedbelowareterminal13to24connectionfunctions.
Terminal Function Terminal Function
13
Zone 1 voltage sensing
19
Zone 5 voltage sensing
14
GroundforZones1and2
20
GroundforZones5and6
15
Zone 2 voltage sensing
21
Zone 6 voltage sensing
16
Zone 3 voltage sensing
22
Zone 7 voltage sensing
17
GroundforZones3and4
23
GroundforZones7and8
18
Zone4voltagesensing
24
Zone 8 voltage sensing
The voltage sensing terminal measures the voltage across a 1k Ohm End-of-Line resistor to ground. Use DMP Model 311 1k
Ohm resistors. Dry contact sensing devices can be used in series (normally-closed) or in parallel (normally-open) with any
of the burglary protection zones.
Each protection zone detects three conditions: Open, Normal, and Short. Listed below are voltage and resistance
parameters for each condition:
Condition Resistance on zone Voltage on positive terminal
Open over 1300 ohms over 2.0 Vdc
Normal 600 to 1300 ohms 1.2 to 2.0 Vdc
Short under 600 ohms under 1.2 Vdc
10.2 Dual EOL
TheXR100SeriesCanadianpanelsupportstheuseofdual1KEOLresistorsonpanelzonesonetoeight.
Two EOL resistors are used so a wire trouble can be indicated during the disarm period.
Whendualend-of-lineoperationischoseninpanelprogramming,normalzoneprocessingoccurs
withthefollowingexception:WhenprocessinganopenzoneandatroubleoralarmmessageisNOT
programmed to be sent for the open state, the panel checks to see if the wire is cut. If the wire is cut,
the panel automatically sends an alarm if armed or trouble is disarmed.
ZONE STATUS
Zone Wires Open Zone Wires Short Contact Normal Contact Open
Disarmed Trouble Trouble Normal Normal
Armed Alarm Alarm Normal Alarm
10.3 Zone Response Time
A condition must be present on a zone for 500 milliseconds before it is detected by the XR100 Series panel. Ensure
detection devices used on the protec tion zones are rated for use with this delay. Zones 1-10 can also be programmed for a
fast response delay of 160 milliseconds.
10.4 Keyswitch Arming Zone
A keyswitch on an Arming type zone allows selected areas to arm and disarm without having to enter a user code.
Powered Zones for 2-Wire Smoke Detectors
11.1 Terminals 25–26 and 27–28
Panel terminals 25 through 28 provide two resettable Class B, Style A, 2-wire powered zones. For programming purposes
the zone numbers are 9 and 10.
Note:Themaximumwirelengthforeitherzone9orzone10is3000feetusing18AWGor1000feetusing22AWG.The
maximumvoltageis14Vdcandmaximumcurrentis1.25mADC.Themaximumlineimpedanceis100Ohms.Themaximum
short circuit current is 56mA.
Whenusingallotherzoneexpansionmodules,useULListedModel309EOLresistors.Thecompatibilityidentierforthe
zones is A.
Note: Do not mix detectors from different manufacturers on the same zone.
Caution: Performing a Sensor Reset momentarily drops power to the devices on Zones 9 and 10. The panel
viewsthesezones(9and10)as“Open”whilethepowerisabsent.
Figure 5: Protection Zone Wiring
1K Ohm
Normally
Closed
1K Ohm
Normally Open
1K Ohm
Combination Normally Open
and Normally Closed
1K Oh
1K Ohm
m
Indicating Device
Zone wires
to Panel
Zones 1-8