Digital Monitoring Products Canadian XR100 Instalační příručka Strana 7

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 36
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 6
XR100 Series Canadian Installation Guide Digital Monitoring Products
1
IntroductIon
Product Specications
1.1 Power Supply
Transformer Input: Model 327-CAN, plug-in — Primary input: 120 Vac, 60 Hz, Secondary output: 16.5 Vac 50 VA
Model FTA7516 ATC Frost from Standex Electronics — Primary input: 120 Vac, 60 Hz,
Secondary output: 16 Vac 75 VA
Standby Battery: 12 Vdc, 1.0 Amps Max. charging current
Models 365, 366, 368, or 369
Replace every 3 to 5 years
Auxiliary: 12 Vdc output at 1.0 Amp Max using Model 327-CAN
Bell Output: 12 Vdc at 1.0 Amp Max using Model 327-CAN
Auxiliary: 12 Vdc output at 1.5 Amp Max using Model FTA7516
Bell Output: 12 Vdc at 1.5 Amp Max using Model FTA7516
All circuits are inherent Power Limited except the red battery wire and AC terminal.
1.2 Communication
• Built-in network communication to DMP Model SCS-1R or SCS-VR Receivers (XR100N only)
• Built-in encrypted communication to DMP Model SCS-1R Receivers
• Built-in Contact ID communication to DMP Model SCS-1R Receivers
• Optional cellular communication to DMP Model SCS-1R or SCS-VR Receivers
• Can operate as a local panel
1.3 Panel Zones
Eight 1k Ohm EOL burglary zones (zones 1 to 8)
Two 3.3k Ohm EOL powered zone with reset (zones 9 and 10)
1.4 Keypad Bus
You can connect up to a total of eight of the following supervised keypads and expansion modules to the keypad bus:
• Alphanumerickeypads • Four-and/orsingle-zoneexpansionmodules
• Single-zonedetectors • Accesscontrolmodules
• WirelessKeypads(maximumof4)
1.5 LX-Bus™
YoucanconnectthefollowingdevicestotheLX-Bus™providedonthepanelorbytheDMP481,462Nand464-263H
InterfaceCardsuptothemaximumnumberofLX-Bus™addresses.SeeAccessoryDevicesinsection3.4.
• Sixteen-,eight-,four-and/orsingle-zoneexpansionmodules • Graphicannunciatormodules
• Model521LXor521LXTSmokeDetectorswithCleanMe • Relayoutputexpansionmodules
• Model2W-BLXor2WT-BLXSmokeDetectors
1.6 Outputs
The XR100 Series provide two Single Pole, Double Throw (SPDT) relay outputs which require the installation of two Model
305relays,eachrated1Ampat30Vdcresistive(powerlimitedsourcesonly).AModel431OutputHarnessisrequiredto
use these outputs.
The XR100 Series also provide four open collector outputs rated for 50mA each. The open collector outputs provide ground
connection for a positive voltage source. A Model 300 Output Harness is required to use these outputs.
1.7 Enclosure Specications
The XR100 Series are shipped in an enclosure with a transformer, End-of-Line resistors, battery leads, user’s guide, and
programming sheets.
Enclosure
Model
Size Color(s) Construction (Cold Rolled Steel)
350 17.5”W x 13.5”H x 3.5”D Gray (G) or Red (R) 18-Gauge
350A 17.5”W x 13.5”H x 3.75”D Gray (G) 18-Gauge with 16-Gauge door
341 12.45”W x 6.55”H x 3.15”D Gray (G) 20-Gauge
Panel Features
2.1 Description
TheDMPXR100SeriesCanadianpanelisaversatile12Vdc,combinedaccesscontrol,burglary,andrecommunicator
panel with battery backup. The XR100 Series provides eight on-board burglary zones and two on-board 12 Vdc Class B
powered zones. The powered zones have a reset capability to provide for 2-wire smoke detectors, relays, or other latching
devices. The XR100 Series can communicate to DMP SCS-1R Receivers using digital dialer, cellular, network, or Contact ID
communication.
Zobrazit stránku 6