XR150/XR350/XR550 Series Programming Guide Digital Monitoring Products
31
OUTPUT OPTIONS
11.8 Entry Output
Enter the output/Favorite number to turn on at the start of the entry delay time. The
output turns off when the area is disarmed or the entry delay time expires. Enter 0 (zero)
to disable.
11.9 Begin Exit Output
This output/Favorite turns on any time an exit delay time starts. The output turns off
when the system arms or when the arming has been stopped. Enter 0 (zero) to disable.
11.10 End Exit Output
This output/Favorite turns on any time an exit delay time ends. The output turns off
when the system disarms. Enter 0 (zero) to disable.
11.11 Ready Output
Enter the output/Favorite number to turn on when all disarmed burglary zones are in a
normal state. The output is turned off when any disarmed burglary type zone is in a bad
state. Enter 0 (zero) to disable. This output is not compatible with Cutoff Outputs.
11.12 Disarmed Output
This output/Favorite turns on when all areas of the panel are disarmed. The output turns
off when an area is armed.
11.13 Telephone Trouble Output
Enter the output/Favorite number to turn on when the phone line monitor on the panel
phone line is lost. Enter 0 (zero) to disable this output.
11.14 Late To Close Output
Enter the output/Favorite number to turn on at the expiration of a Closing schedule. The
output activates simultaneously with the CLOSING TIME! keypad display. The output is
turned off when the area is armed, the Closing is extended, or the schedule is changed.
Enter 0 (zero) to disable this output.
11.15 Device Fail Output
Enter the output/Favorite number to turn on when an addressed device fails to respond to
polling from the panel. A Missing Device report is sent to the receiver. The output is turned
off when the device responds to polling or is removed from programming in the system.
Enter 0 (zero) to disable this output and LX-Bus™ device fail reporting to the receiver. If
any addressed device is unsupervised, this output cannot be used.
11.16 Sensor Reset Output
Enter the output/Favorite number to turn on when a Sensor Reset is performed at a
keypad. The output turns off automatically 5 seconds later. This function can be used to
reset smoke detectors that are operated by an external power supply through a Model 716
Output Expander Module. Enter 0 (zero) to disable this output.
11.17 Closing Wait Output
Enter the output/Favorite number to turn on for approximately four (4) seconds when
Closing Wait is programmed as YES and the panel successfully communicates the closing
message at arming. If the closing message does not communicate successfully, this output
does not turn on.
11.18 Arm-Alarm Output
Enter the output/Favorite number to turn on steady when any area of the system is armed.
If an alarm occurs causing the keypads to turn Red, this output pulses and continues to
pulse for approximately ve (5) minutes after the panel is disarmed. Enter 0 (zero) to
disable.
Wireless Outputs
The Arm-Alarm Output is compatible with the Model 1117 Wireless LED Annunciator
and the Model 1116 Wireless Relay Output connected to a Model 572 Indicator LED.
When the Model 1117 is battery operated, the LED is off when the system is armed to
conserve battery life. If an alarm occurs, the output ashes quickly.
When using the Model 1116 connected to a Model 572, the LED is on when the system
is armed. If an alarm occurs, the output pulses.
To operate the Arm-Alarm output within one second, program a fast response number
from 480 to 499. Fast response operation reduces overall wireless output battery life.
To operate the Arm-Alarm output within 15 seconds, program a slow response number
from 450 to 474. Slow response operation increases overall wireless output battery
life.
ENTRY OUT: 0
BEG EXIT OUT: 0
END EXIT OUT: 0
READY OUT: 0
DISARMED OUT: 0
PH TRBL OUT: 0
LATE CLS OUT: 0
DVC FAIL OUT: 0
SNSR RST OUT: 0
CLS WAIT OUT: 0
ARM-ALARM OUT: 0