Digital Monitoring Products XTL/XTLC Programming Guide
20
OUTPUT OPTIONS
10.9 Disarmed Output
This output/Favorite turns on when all areas of the panel are disarmed. The output
turns off when an area is armed.
10.10 Burglary Output
This output/Favorite turns on any time a burglary zone goes into alarm. The output
turns off when the area in which the alarm occurred disarms and no other burglary zones
are in alarm. Enter 0 (zero) to disable this output.
10.11 Ready Output
This output/Favorite turns on whenever all disarmed zones are in a normal state. The
output turns off when any disarmed zone is in a bad state. Enter 0 (zero) to disable.
10.12 Arm-Alarm Output
Enter the output/Favorite to turn on steady when any area of the system is armed. If
an alarm occurs causing the keypads to turn Red, this output pulses and continues to
pulse for approximately three (3) minutes after the panel is disarmed. Enter 0 (zero) to
disable.
Wireless Outputs
The Arm-Alarm Output is compatible with the Model 1117 Wireless LED
Annunciator and the Model 1116 Wireless Relay Output connected to a Model 572
Indicator LED.
When the Model 1117 is battery operated, the LED is off when the system is
armed to conserve battery life. If an alarm occurs, the output ashes quickly.
When using the Model 1116 connected to a Model 572, the LED is on when the
system is armed. If an alarm occurs, the output pulses.
To operate the Arm-Alarm output within one second, program a fast response
number from 41 to 44. Fast response operation reduces overall wireless output
battery life.
To operate the Arm-Alarm output within 15 seconds, program a slow response
number from 31 to 34. Slow response operation increases overall wireless output
battery life.
10.13 Heat Saver Temperature
Enter the desired temperature setting for all Z-Wave thermostats when the system
is armed ALL or AWAY. When the system is disarmed the thermostats return to their
previous settings. The range is 55-95 degrees. Enter 0 (zero) to disable.
10.14 Cool Saver Temperature
Enter the desired temperature setting for all Z-Wave thermostats when the system
is armed ALL or AWAY. When the system is disarmed the thermostats return to their
previous settings. The range is 55-95 degrees. Enter 0 (zero) to disable.
DISARMED OUT: 0
BURGLARY OUT: 0
READY OUT: 0
ARM-ALARM OUT: 0
HEAT SAVER
TEMPERATURE: 0
COOL SAVER
TEMPERATURE: 0