Digital Monitoring Products XTL/XTLC Programming Guide
30
ZONE INFORMATION
13.13.3 Output Action
Entering an Output Number displays this option that allows you to assign an output
action. A description of the available output actions is given below:
STEADY - The output is turned on and remains on until the area is disarmed, an output
cutoff time expires, or the output is reset from the keypad User Menu.
PULSE - The output alternates one second on and one second off until the area is
disarmed, an output cutoff time expires, or the output is reset from the keypad User
Menu.
MOMENTARY - The output is turned on only once for one second.
FOLLOW - The output is turned on and remains on while the zone is in an off normal, or
bad condition. When the zone restores, the output is turned off.
After you have selected the Message To Transmit, the display prompts you for the same
three selections for Disarmed Short, Armed Open, and Armed Short conditions. If the
zone is a 24-hour type, only the Armed Open and Armed Short conditions are displayed.
When you have programmed all of the zone conditions, the Swinger Bypass selection is
then dis played.
13.14 Swinger Bypass
Selecting YES allows the zone to be swinger bypassed by the panel according to the
programming in Swinger Bypass Trips and Reset Swinger Bypass. The Bypassed zone
displays in the keypad Status List. Selecting NO disables swinger bypassing for this zone.
How it works
If within one hour, a zone trips the total number of times as specied in Swinger Bypass
Trips, the panel bypasses it until the following conditions occur; the area in which
the zone is assigned is disarmed, the zone is manually reset through the Bypass Zones
keypad User Menu function, the zone remains normal for one hour and the Reset Swinger
Bypass is YES.
If the zone trips fewer than the specied times within one hour of the rst trip, the
bypass trip counter returns to 0 (zero) and the process must be repeated.
A report of the swinger bypass is sent to the receiver if Bypass Reports is YES.
13.15 Prewarn Address
Option is only shown for an Exit zone.
At the start of the entry delay, all keypad addresses dis play ENTER CODE:-. If you want
the prewarn to sound at all addresses, leave the default as shown.
To delete an address, press the matching number on the keypad. To disable prewarning
at all keypads, press a top row key to clear the addresses shown. Press the COM MAND
key when the address selection is com plete.
Note: The prewarn tone stops at the keypad when the rst digit of a user code is
entered. If, within ve seconds, a valid user code is not entered or an invalid user code
is entered, the prewarn tone begins sounding again. Fifteen seconds must elapse before
entering a digit silences the prewarn tone again.
13.16 Entry Delay
Option is only shown for an Exit zone. Select the entry delay timer for this zone. Entry
delay timers 1 and 2 are programmed in Entry Delay in the System Options menu.
13.17 Cross Zone
Select YES to enable cross-zoning for this zone. Cross-zoning requires this zone to trip
twice, or this zone and another cross-zoned zone to trip, within a programmed time
before an alarm report is sent to the receiver.
Note: To operate correctly, all cross-zone zones need to be programmed as the same
zone type.
When a cross-zoned zone trips, the Output action assigned to the zone activates. See the
Bell Action section. The cross-zone time specied in System Options begins to count down.
See the Cross-Zone Time section. If another cross-zoned zone in the system faults, or if the
rst zone restores and faults again before the cross-zone time expires, the bell turns on
and the panel sends an alarm report.
ACTION:
NO YES
STD PLS MOM FOLW
SWGR BYP NO YES
PREWARN: 12345
ENTRY DELAY: 1
CRS ZONE NO YES