Digital Monitoring Products XT Series Programming Guide
44
APPENDIX
17.9 Zone Type Defaults
The XT30/XT50 panel contains 11 default zone types that provide the most commonly selected functions
for their applications. All zone types can be customized by changing the variable options listed below.
Key Fob - Indicates if a DMP key fob is programmed.
Type - These are the abbreviations displayed on the keypad for the zone types.
Area - For a ALL/PERIM or HOME/SLEEP/AWAY system, this is either Interior, Bedroom, or Perimeter. For
an AREA system use 1 to 6.
Wireless - These options are for use with the DMP Wireless Receiver.
Contact - Indicates if the DMP Universal Transmitter is programmed to use the internal or external
contact.
External Contact N/O? - Identies whether externally installed contacts are programmed as a normally
open (N/O) or normally closed (N/C) circuit. Y = N/O Contacts. N = N/C Contacts.
1114 Contact - Indicates if the 1114 Zone Expander is programmed for contact(s) 1, 2, 3, or 4.
Supervision Time - Selects the number of minutes for DMP wireless supervision.
LED Operation - Identies Wireless Two-Button transmitter LED operation.
Disarm-Disable - Identies 1126 or 1127 PIR operation.
PIR Pulse Count - Selects the number of pulse counts the 1126 or 1127 uses before sending a short
message.
Sensitivity - Sets the sensitivity for the 1126 or 1127 PIR.
Message - A = alarm report, T = trouble report,