XR100 Series Programming Guide Digital Monitoring Products
21
Device Setup
734 Site Code Programming
6.18.9 Site Code Position
Enterthesitecodestartpositioninthedatastring.PressanytoprowSelectkeyto
enteranumberbetween0-255.Defaultis1.
6.18.10 Site Code Length
Enterthenumberofcharactersthesitecodecontains.PressanytoprowSelectkey
toenteranumberbetween1-16.Defaultis8.
6.18.11 User Code Position
DenetheUserCodestartbitposition.PressanytoprowSelectkeytoentera
numberbetween0-255.Defaultis9.
6.18.12 User Code Length
DenethenumberofUserCodebits.PressanytoprowSelectkeytoentera
customnumber.Customnumberscanonlybeanumberbetween16-32.Ona
734N/
734N-WiFi
module,customnumberscanbebetween1-255.Thedefaultis16.
6.18.13 Require Site Code
PressthetoprowSelectkeyunderYEStouseasitecode.
InadditiontoUserCodeverication,dooraccessisonlygrantedwhenanyonesite
codeprogrammedattheSITECODEENTRYoptionmatchesthesitecodereceivedin
the Wiegand string.
6.18.13.1 Site Code Display
734 Module: Youcanprogramupto8three-digitsitecodes.Sitecoderangeis
0-999.Anypreviouslyprogrammedsitecodesdisplay.Dashesrepresentblank site
codes. Default is blank.
Note: A card with a site code greater than three digits cannot be used. Use only
cards with three-digit site codes.
734N/734N-WiFi Module:Youcanprogramupto8ve-digitsitecodes.Site code
rangeis1-65535.Anypreviouslyprogrammedsitecodesdisplay.SiteCode 1
defaultsto127.SiteCodes2-8defaulttoblank.Dashesrepresentblanksite
codes.
SiteCode1displaysrst.EnterasitecodenumberfollowedbytheCommandkey
toadvancetothenextoption,SiteCode2.Todeleteanexistingsitecode, press
anySelectkey.EitherenteranewsitecodefollowedbyCommand,or press
Command to leave blank and continue to the next site code. Repeat these steps
tochange,delete,oraddupto8sitecodes
.
6.18.14 Number of User Code Digits
The734modulerecognizesusercodesfromfourtotendigitsinlength.The
734N/
734N-WiFi
modulerecognizesusercodesfrom1-10digitsinlength.Press
anytoprowSelectkeytoenterausercodedigitlengthbetween4-10digits.This
number must match the user code number length being used by the panel. Default
is5.ForanXR100AreaSystem,use4to10digits(typically5).
Anyselectionabove5digitsrequireentryofthecustomcarddenitionswith
custom site and user code positions for the Wiegand string. When searching the bit
stringfortheusercode,thedigitsareidentiedandreadfromlefttoright.
SITE CODE
POSITION: 1
SITE CODE
LENGTH: 8
USER CODE
POSITION: 9
USER CODE
LENGTH: 16
REQUIRE SITE
CODE? NO YES
SITE CODE 1:
(1-65,535) 127
NO OF USER CODE
DIGITS: 5
SITE CODE 1: -