Digital Monitoring Products Canadian XR100 Manuál s instrukcemi Strana 40

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 78
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 39
Digital Monitoring Products XR100 Series Programming Guide
32
Bell OptiOns
Bell Options
10.1
BELL OPTIONS
Bell Options
This section allows you to program the panel bell output functions.
10.2
BELL CUTOFF: 15
Bell Cutoff Time
Enterthemaximumtimefrom1to99minutestheBellOutputremainson.Ifthe
areaisdisarmed,thecutofftimeresets.Enter0(zero)toprovidecontinuousbell
output. The default is 15 minutes.
Note: For SIA CP-01 False Alarm Reduction Installations, the Bell Cutoff Time
must be set to a minimum of six (6) minutes.
10.3
BELL TST NO YES
Automatic Bell Test
SelectYEStoturnontheBellOutputfor2secondseachtimethesystem is
com pletely armed from a keypad. This test is delayed until the Closing Wait
acknowledgeisreceived(ifprogrammed).IftheClosingWaitacknowledgeisnot
receivedwithin90seconds,thebelltestdoesnotoccur.Armingperformedfroman
ArmingzoneorfromRemoteLink™doesnotactivatetheBellTest.
10.4
BELL OUTPUT: 0
Bell Output
EntertheoutputnumberwhenneededtofollowthepanelBellOutputoperation
forallactionandoffconditions.Enter0(zero)todisable.
Note:WhenBELLACTIONissettoTforTemporalCode3,theBellOutputactionfor
anLX-Busoutputispulse.
Note:BellOutputshouldnotbeprogrammedforaModel1135WirelessSirenwhen
programmed in Output Information to Trip with Panel Bell.
10.5
BELL ACTION . . . . .
Bell Action
ThissectiondenesthetypeofBellOutputforzonealarms.PressCOMMANDto
display the default Bell Output for each zone type. Press any Select key and enter
SforaSteadyBellOutput,PforaPulsedoutput,TforaTemporalCode3output,
and N for no Bell Output.
Note: Trouble conditions do not activate the Bell Output.
10.5.1
FIRE TYPE: P
Fire Bell Action
DenesBellActionforFireTypezones.ThedefaultisP.
10.5.2
BURGLARY TYPE: S
Burglary Bell Action
DenesBellActionforBurglaryTypezonesandExitErroroutput.Thedefaultisset
at S.
10.5.3
SUPRVSRY TYPE: N
Supervisory Bell Action
DenesBellActionforSupervisoryTypezones.ThedefaultissetatN.
10.5.4
PANIC TYPE: N
Panic Bell Action
DenesBellActionforPanicTypezones.ThedefaultissetatN.
10.5.5
EMERGNCY TYPE: N
Emergency Bell Action
DenesBellActionforEmergencyTypezones.ThedefaultissetatN.
10.5.6
AUXLRY 1 TYPE: N
Auxiliary 1 Bell Action
DenesBellActionforAuxiliary1Typezones.ThedefaultissetatN.
10.5.7
AUXLRY 2 TYPE: N
Auxiliary 2 Bell Action
DenesBellActionforAuxiliary2Typezones.ThedefaultissetatN.