Digital Monitoring Products XR100 Series Programming Guide
46
Zone InformatIon
Zone Information
18.1
ZONE INFORMATION
Zone Information
ZoneInformationallowsyoutodenetheoperationofeachprotectionzoneused
in the system. All protection zones, whether located on a panel, keypad, or zone
expander are programmed the same way.
18.2
ZONE NO: -
Zone Number
Enterthenumberofthezoneyouintendtoprogram.Availablezonenumbersare
shown in the table below. The keypad zone numbers begin with the keypad address
andarefollowedbytheparticularzonefromthatkeypad.Forexample,a7073at
keypadaddress7wouldprovidezones71,72,73,and74.
Press COMMAND to enter a zone name.
Address Programming Zone Number
Panel 1-10
1 11-14
2 21-24
3 31-34
4 41-44
5 51-54
6 61-64
7 71-74
8 81-84
1100 Series Key Fob 400-449
LX-Bus 1 500-599
Note:For1100SeriesKeyFobzones(400-449),programmingcontinuesatthe1100
Series Key Fobs Section.
18.3
* UNUSED *
Zone Name
Zonenamescanhaveupto32alphanumericcharacters.Anamemustbegivento
each zone in the system. The name can display at the keypads during arming and
disarmingsotheuserdoesnothavetomemorizezonenumbers.Userscanasso-
ciate a zone name with a particular protection point. A zone that is not part of the
system must be marked unused.
Toaddazonenametothesystem,pressanySelectkeyandthenenterupto32
characters for the new zone name. Press COMMAND to continue.
To mark a zone unused, de lete the old name by pressing a top row Select key, then
presstheCOMMANDkey.Theprogrammerautomaticallyprogramsthenameas*
UNUSED*.IfyouhavealreadyclearedZoneInformationduringInitialization,the
zonesaremarked*UNUSED*.