30
SyStem OptiOnS
9.19
KEYPAD PANIC KEYS
ENABLED: NO YES
Enable Keypad Panic Keys
Thisoptionallowsthetwo-buttonpanickeyoperationselectedatthekeypadto
sendthePanic,Emergency,orFiremessagetothecentralstationreceiver.Select
YEStoenablethetwo-buttonpanicoperationtooperate.Todisablethetwo-
buttonpanicoperation,selectNO.DefaultisYES.
9.20
OCCUPIED
PREMISE: NO YES
Occupied Premise
ForAll/PerimeterorHome/Sleep/Awaysystems,selectYEStoallowthepanelto
automaticallydisarmtheinteriorarea(s)whenarmingallareasandaperimeter
zone is not tripped during the exit delay. Select NO to disable this feature. Default
isYES.
Note:WithaHome/Sleep/AwaywithGuestarmingsystem,thisfeatureonly
applies to the main system.
9.21
ENHANCED ZONE
TEST: NO YES
Enhanced Zone Test
SelectYEStoallowenhancedzonetestoperation.ThedefaultisNO.
Enhancedoperationallows:
•PanicTestandWalkTestfunctionscanberestrictedtooperateonlyduringan
Area32,Shift4scheduleifprogrammed.Ifnoscheduleisentered,thewalk
test always operates.
•AVerifymessageissenteachtimeazoneistested.Ifazoneistrippedmultiple
times,aVerifymessageissentforeachtrip.ThisallowstheCentralStationto
record the number of devices per zone.
•TheVerifymessageforeachzonetestissentatthetimethetripoccursinstead
of at the end of Walk Test.
•TheSystemTestBeginandSystemTestEndCentralStationmessagesindicate
the type of zone being tested. The System Test Begin message also includes the
user name and number.
9.22
SEND 16 CHAR
NAMES: NO YES
Send 16 Character Names
Thisoptionallowscentralstationstoselectbeingsenteithertherst16characters
ofthenameeldortheentireprogrammedname,upto32characters,foruser
name,userprole,zonename,areaname,outputname,andgroupname.
SelectYEStohavetherst16charactersofthenameeldsenttothecentral
station. Select NO to send the exact number of characters entered in the name
eldfrom1uptothemaximumof32characters.DefaultisYES.
Note:Using32characternamesincreasesthelengthoftheDMPSerial3message
fromthepaneltothereceiver.TheSCS-1Rreceiverdoesnotrequireanupdateto
pass these messages to the Host Automation System of the Central Station. Before
usingnameslongerthan16characters,determinewhethertheHostAutomation
SystemofyourCentralStationcanaccept17to32characternames.Ifnot,only
use16characternames.
9.23
KEYPAD ARMED LED
ALL
Keypad Armed LED
This option displays only when using an Area system. Press any top row key to
selecttheoperationoftheArmedLEDonthekeypad.SelectALLtorequireall
keypaddisplayareastobearmedbeforethekeypadArmedLEDturnson.Select
ANYtoturnonthekeypadArmedLEDwhenanykeypaddisplayareaisarmed.
DefaultisALL.
9.24
USE FALSE ALARM
QUESTION NO YES
Use False Alarm Question
SelectYEStodisplayISTHISAFALSEALARM?NOYESatthekeypadinplaceof
CANCELVERIFYwhenaburglaralarmoccurs.ThisoperatesforALL/PERIMand
HOME/SLEEP/AWAYarmingsystems.DefaultisNO.
9.25
ALLOW OWN USER
CODE CHG? NO YES
Allow Own User Code Change
This option allows users without user code authority to change their own user code.
WhenYESisselected,theUserCodemenudisplaysUSERCODE:*****atthekeypadto
allow that user to change their own code. If NO is selected, the user cannot change
their personal user code. Default is NO.
KEYPAD ARMED LED
ALL ANY
Zobrazit stránku 37