XR100 Series Programming Guide Digital Monitoring Products
57
Stop
19.1
STOP
Stop
Save Programming
WHEN ANY PANEL PROGRAMMING IS CHANGED, THE STOP ROUTINE MUST BE
RUN AND ‘SAVING PROGRAM’ MUST DISPLAY ON THE KEYPAD IN ORDER TO SAVE
THE PROGRAMMING CHANGES.
At the STOP option, pressing any Select key allows you to exit the Programmer
function of the panel. When selected, the panel performs an internal reset and
exits the programmer.
The STOP routine causes the following conditions to occur:
•All1100SeriesDMPWirelesstransmittersareresettoNORMAL
•ThepanelStatusListiscleared
During the reset, all keypad displays are momentarily blank for two seconds. After
the reset, the programming function terminates and the keypads return to the
status list display.
The STOP option does not disarm the system. Any new areas or zones that were
added during programming are not armed until the system is disarmed and armed
again.
Power Up
For60secondsafterpowerupontheXR100Seriespanel,anyzonetransitionsare
notrecognized.Normalzoneprocessingresumesattheendofthe60seconds.
Set Lockout Code
20.1
SET LOCKOUT CODE
Set Lockout Code
PressingCOMMANDattheSTOPoptiondisplaysSETLOCKOUTCODE.Thisallows
you to program a code that is then required to gain access to the panel internal
Programmer through the keypad. You can change this code at any time to any
combinationofnumbersfromthreetovedigitslong.Youdonotneedtoenter
leading zeros when using the lockout code. Initializing the panel does not clear a
LockoutCode.LockoutCodescanbechangedthroughRemoteLink.
Once you have changed the code, it is important to write it down somewhere
andstoreitinasafeplace.LostLockoutCodesrequirethepaneltobesentback
toDMPforrepair.YoumaycancelaLockoutCodebyentering00000attheSet
LockoutCodecommand.
Lockout Code restriction
DonotsetaLockoutCodehigherthan65535.